Показать сокращенную информацию

Aliaksandr, Mialdun
Mounir M. Bou-Ali
Marco, Braibanti
Fabrizio, Croccolo
Ane, Errarte
José, Miguel Ezquerro
José, Javier Fernández
Loreto, García-Fernández
Quentin, Galand
Yuri, Gaponenko
Fina, Gavaldà
Werner, Köhler
Tatyana, Lyubimova
José María Ortiz, de Zárate
Jacobo, Rodríguez
Xavier, Ruiz
Ilya I. Ryzhkov
Marcel, Schraml
Valentina, Shevtsova
Stephan, Van Vaerenbergh
Viktar, Yasnou
Henri, Bataller
2021-08-13T09:30:27Z
2021-08-13T09:30:27Z
2020-11
Aliaksandr, Mialdun. Data quality assessment of Diffusion Coefficient Measurements in ternary mIXtures 4 (DCMIX4) experiment [Текст] / Mialdun Aliaksandr, Mounir M. Bou-Ali, Braibanti Marco, Croccolo Fabrizio, Errarte Ane, Miguel Ezquerro José, Javier Fernández José, García-Fernández Loreto, Galand Quentin, Gaponenko Yuri, Gavaldà Fina, Köhler Werner, Lyubimova Tatyana, de Zárate José María Ortiz, Rodríguez Jacobo, Ruiz Xavier, Ilya I. Ryzhkov, Schraml Marcel, Shevtsova Valentina, Van Vaerenbergh Stephan, Yasnou Viktar, Bataller Henri // Acta Astronautica. — 2020. — Т. 176. — С. 204-215
00945765
https://www.sciencedirect.com/science/article/abs/pii/S009457652030388X
https://elib.sfu-kras.ru/handle/2311/142463
Thermodiffusion, which leads to a component separation in a mixture due to the thermal gradient, still does not have an unambiguous microscopic picture. Therefore, experimental studies, especially in convection free environment, are important. As part of the 4th campaign on the DCMIX project, thermodiffusion experiments on three compositions of the toluene-methanol-cyclohexane ternary mixture, on a mixture of fullerene-tetralintoluene and on a mixture of polystyrene-toluene-cyclohexane have been performed in microgravity conditions on board the International Space Station. A binary mixture of polystyrene-toluene has been filled into the companion cell for the campaign. The Selectable Optical Diagnostics Instrument (SODI), wich is a two-wavelength Mach-Zehnder interferometer for the ternary mixtures, plus a monochromatic Mach-Zehnder interferometer for the binary mixture, has been used in order to obtain the temperature and the concentration fields in the cells. Precisely, it is a 5-steps phase-shifting interferometry technique which is implemented with SODI, producing by means of laser illumination a set of 5 phase-shifted images of /2 between them as function of the time. A total of 58 runs of various durations and at different mean temperatures have been conducted. Here, we evaluate the contrast of the interferograms, the quality in the phase stepping, the stability of the thermal regulation of the experiments and the level of environmental disturbances on board the space station during the campaign.
International space station
Thermodiffusion
Ternary mixtures
Phase-shifting interferometry
Thermal regulation stability
Data quality assessment of Diffusion Coefficient Measurements in ternary mIXtures 4 (DCMIX4) experiment
Journal Article
Published Journal Article
204-215
2021-08-13T09:30:27Z
10.1016/j.actaastro.2020.06.020
Институт космических и информационных технологий
Кафедра прикладной математики и компьютерной безопасности
Acta Astronautica
Q1