The paper presents analysis of the results of 873 template measurements used for inspection in wagon depo. The data obtained were analyzed to confirm the stability of inspection results. It is shown that the measurement and determination of the final result by calculating the average value lead to misleading results. Random factors affecting measurements are also presented. The subjective factor in this process is supplied from the calibrator. To make measurement process more stable, we need to reduce the effect of these factors. One of the ways to improve measurement process and make it more stable is its automatization. Improving the accuracy of measurements is one of the main objectives concerning this issue.
Metrology
Calibration
Automation
Standards
Manufacturing
Couplers
Industrial engineering
Stabilization of calibration metrological characteristics of technological inspection tools
Journal Article
Journal Article Preprint
55.01.77
2018-02-07T07:28:45Z
10.1109/ICIEAM.2016.7911599
Институт нефти и газа
Кафедра технологических машин и оборудования нефтегазового комплекса
Industrial Engineering, Applications and Manufacturing (ICIEAM), International Conference on
без квартиля
без квартиля


Файлы в этом документе

Thumbnail

Данный элемент включен в следующие коллекции

Показать сокращенную информацию